HONEYWELL AQ1000TN2 Non-Programmable Communicating Thermost.
Description
Honeywell AQ1000TN2 thermostat controls the ambient air or floor temperature in hydronic heating applications. To provide zoning control, it communicates with and is powered by a Honeywell AQ2000 series zoning module.
Features
- Two-wire polarity-insensitive non-programmable network communicating thermostat
- User buttons feature liquid crystal display as well as outdoor, indoor and floor temperature displays
- Floor temperature sensing with minimum and maximum limits (when used with optional AQ12C20 Slab/Floor Sensor ( sold separately))
- Selectable temporary and permanent backlight
Product Specifications
- Application
- Hydronic single-stage zoning heat
- Dimensions (in.)
- 2.8 in wide x 4.6 in high x 1.0 in deep
- Dimensions (mm)
- 7 cm wide x 12 cm in high x 2.5 cm deep
- Weight (lb)
- 0.2 lb
- Weight (kg)
- 0.1 kg
- Item Type
- Product
- Mounting
- Vertical
- Tradeline Value
- Tradeline
- User Interface
- DIP Switches
- Electrical Connections
- Wire-clamp screw terminals
- Operating Humidity Range (% RH)
- 5 to 90% RH, non-condensing
- Shipping and Storage Temperature Range (F)
- -30 C to 55 C
- Shipping and Storage Temperature Range (C)
- -20 F to 130 F
- Sensor Element
- Thermistor
- Differential Temperature (F)
- ± 1 F
- Differential Temperature (C)
- ±0.5 C
- Color
- Premier White®
- Ambient Temperature Range (F)
- 32 F to 158 F
- Ambient Temperature Range (C)
- 0 C to 70 C
- Power Method
- Powered (24 Vdc) by AQ zoning module
- Terminal Designations
- TH, TH, Sensor, Sensor
- Display
- LCD Display; Icons in display: Heat On, Vacation Mode, Comfort/Unoccupied, Keypad Lock, Set point; Temperatures Displayed: Indoor, Setpoint, Outdoor
- Temperature Control Mode Selections
- A for Ambient Air; “F” for Floor; “AF” for Ambient & Floor.
- Zones
- Single or Multi-zone; Network Zoning available
- Setting Temperature Range (F)
- Ambient and Floor-40 F to 100 F
- Setting Temperature Range (C)
- Ambient and Floor-5 C to 38 C
- Network Bus
- Low voltage, Class II, 2-wire polarity-insensitive, digital communicating link to AQ2000 series zoning modules.
- External Sensors Available
- Floor Sensor – 10 Kohm NTC thermistor at 25 C (77 F) +/- 0.5F (+/-0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, beta=3892. Lead Length: 10 ft. (3050 mm) with rating 58 F to 230 F (-50 C to 110 C)
- Outdoor Temperature Display Range (F)
- -58 F to 149 F
- Outdoor Temperature Display Range (C)
- -50C to 65 C